ICD-10-CM Codes
›
-
S00-T88
Injury, poisoning and certain other consequences of external causes
›
-
T80-T88
Complications of surgical and medical care, not elsewhere classified
›
-
T84-
Complications of internal orthopedic prosthetic devices, implants and grafts
›
-
2021 ICD-10-CM Diagnosis Code T84.010S
2021 ICD-10-CM Diagnosis Code T84.010S
Broken internal right hip prosthesis, sequela
2016 2017 2018 2019 2020 2021 Billable/Specific Code POA Exempt
- T84.010S is a billable/specific ICD-10-CM code that can be used to indicate a diagnosis for reimbursement purposes.
- The 2021 edition of ICD-10-CM T84.010S became effective on October 1, 2020.
- This is the American ICD-10-CM version of T84.010S - other international versions of ICD-10 T84.010S may differ.
The following code(s) above
T84.010S contain annotation back-references
Annotation Back-References
In this context, annotation back-references refer to codes that contain:
- Applicable To annotations, or
- Code Also annotations, or
- Code First annotations, or
- Excludes1 annotations, or
- Excludes2 annotations, or
- Includes annotations, or
- Note annotations, or
- Use Additional annotations
that may be applicable to
T84.010S:
- S00-T88
2021 ICD-10-CM Range S00-T88
Injury, poisoning and certain other consequences of external causesNote- Use secondary code(s) from Chapter 20, External causes of morbidity, to indicate cause of injury. Codes within the T section that include the external cause do not require an additional external cause code
Use Additional- code to identify any retained foreign body, if applicable (Z18.-)
Injury, poisoning and certain other consequences of external causes - T80-T88
2021 ICD-10-CM Range T80-T88
Complications of surgical and medical care, not elsewhere classifiedType 2 Excludes- any encounters with medical care for postprocedural conditions in which no complications are present, such as:
- artificial opening status (Z93.-)
- closure of external stoma (Z43.-)
- fitting and adjustment of external prosthetic device (Z44.-)
- burns and corrosions from local applications and irradiation (T20-T32)
- complications of surgical procedures during pregnancy, childbirth and the puerperium (O00-O9A)
- mechanical complication of respirator [ventilator] (J95.850)
- poisoning and toxic effects of drugs and chemicals (T36-T65 with fifth or sixth character 1-4 or 6)
- postprocedural fever (R50.82)
- specified complications classified elsewhere, such as:
- cerebrospinal fluid leak from spinal puncture (G97.0)
- colostomy malfunction (K94.0-)
- disorders of fluid and electrolyte imbalance (E86-E87)
- functional disturbances following cardiac surgery (I97.0-I97.1)
- intraoperative and postprocedural complications of specified body systems (D78.-, E36.-, E89.-, G97.3-, G97.4, H59.3-, H59.-, H95.2-, H95.3, I97.4-, I97.5, J95.6-, J95.7, K91.6-, L76.-, M96.-, N99.-)
- ostomy complications (J95.0-, K94.-, N99.5-)
- postgastric surgery syndromes (K91.1)
- postlaminectomy syndrome NEC (M96.1)
- postmastectomy lymphedema syndrome (I97.2)
- postsurgical blind-loop syndrome (K91.2)
- ventilator associated pneumonia (J95.851)
Use Additional- code for adverse effect, if applicable, to identify drug (T36-T50 with fifth or sixth character 5)
Complications of surgical and medical care, not elsewhere classified - T84
ICD-10-CM Diagnosis Code T84
Complications of internal orthopedic prosthetic devices, implants and grafts
2016 2017 2018 2019 2020 2021 Non-Billable/Non-Specific Code
Type 2 Excludes- failure and rejection of transplanted organs and tissues (T86.-)
- fracture of bone following insertion of orthopedic implant, joint prosthesis or bone plate (M96.6)
Complications of internal orthopedic prosthetic devices, implants and grafts - T84.01
ICD-10-CM Diagnosis Code T84.01
Broken internal joint prosthesis
2016 2017 2018 2019 2020 2021 Non-Billable/Non-Specific Code
Applicable To- Breakage (fracture) of prosthetic joint
- Broken prosthetic joint implant
Type 1 Excludes- periprosthetic joint implant fracture (M97.-)
Broken internal joint prosthesis
Present On AdmissionPOA Help
"Present On Admission" is defined as present at the time the order for inpatient admission occurs — conditions that develop during an outpatient encounter, including emergency department, observation, or outpatient surgery, are considered POA.
- T84.010S is considered exempt from POA reporting.
ICD-10-CM T84.010S is grouped within Diagnostic Related Group(s) (MS-DRG v38.0):
- 922 Other injury, poisoning and toxic effect diagnoses with mcc
- 923 Other injury, poisoning and toxic effect diagnoses without mcc
Convert T84.010S to ICD-9-CM
Code History
- 2016 (effective 10/1/2015): New code (first year of non-draft ICD-10-CM)
- 2017 (effective 10/1/2016): No change
- 2018 (effective 10/1/2017): No change
- 2019 (effective 10/1/2018): No change
- 2020 (effective 10/1/2019): No change
- 2021 (effective 10/1/2020): No change
ICD-10-CM Codes Adjacent To T84.010S
T83.9 Unspecified complication of genitourinary prosthetic device, implant and graft
T84 Complications of internal orthopedic prosthetic devices, implants and grafts
T84.0 Mechanical complication of internal joint prosthesis
T84.01 Broken internal joint prosthesis
T84.010 Broken internal right hip prosthesis
T84.010S
…… sequela
T84.011 Broken internal left hip prosthesis
T84.012 Broken internal right knee prosthesis
T84.013 Broken internal left knee prosthesis
Reimbursement claims with a date of service on or after October 1, 2015 require the use of ICD-10-CM codes.