ICD-10-CM Codes
›
-
S00-T88
Injury, poisoning and certain other consequences of external causes
›
-
T80-T88
Complications of surgical and medical care, not elsewhere classified
›
-
T85-
Complications of other internal prosthetic devices, implants and grafts
›
-
2022 ICD-10-CM Diagnosis Code T85.610S
2022 ICD-10-CM Diagnosis Code T85.610S
Breakdown (mechanical) of cranial or spinal infusion catheter, sequela
2016 2017 - Revised Code 2018 2019 2020 2021 2022 Billable/Specific Code POA Exempt
- T85.610S is a billable/specific ICD-10-CM code that can be used to indicate a diagnosis for reimbursement purposes.
- Short description: Breakdown of cranial or spinal infusion catheter, sequela
- The 2022 edition of ICD-10-CM T85.610S became effective on October 1, 2021.
- This is the American ICD-10-CM version of T85.610S - other international versions of ICD-10 T85.610S may differ.
The following code(s) above
T85.610S contain annotation back-references
Annotation Back-References
In this context, annotation back-references refer to codes that contain:
- Applicable To annotations, or
- Code Also annotations, or
- Code First annotations, or
- Excludes1 annotations, or
- Excludes2 annotations, or
- Includes annotations, or
- Note annotations, or
- Use Additional annotations
that may be applicable to
T85.610S:
- S00-T88
2022 ICD-10-CM Range S00-T88
Injury, poisoning and certain other consequences of external causesNote- Use secondary code(s) from Chapter 20, External causes of morbidity, to indicate cause of injury. Codes within the T section that include the external cause do not require an additional external cause code
Use Additional- code to identify any retained foreign body, if applicable (Z18.-)
Injury, poisoning and certain other consequences of external causes - T80-T88
2022 ICD-10-CM Range T80-T88
Complications of surgical and medical care, not elsewhere classifiedType 2 Excludes- any encounters with medical care for postprocedural conditions in which no complications are present, such as:
- artificial opening status (Z93.-)
- closure of external stoma (Z43.-)
- fitting and adjustment of external prosthetic device (Z44.-)
- burns and corrosions from local applications and irradiation (T20-T32)
- complications of surgical procedures during pregnancy, childbirth and the puerperium (O00-O9A)
- mechanical complication of respirator [ventilator] (J95.850)
- poisoning and toxic effects of drugs and chemicals (T36-T65 with fifth or sixth character 1-4 or 6)
- postprocedural fever (R50.82)
- specified complications classified elsewhere, such as:
- cerebrospinal fluid leak from spinal puncture (G97.0)
- colostomy malfunction (K94.0-)
- disorders of fluid and electrolyte imbalance (E86-E87)
- functional disturbances following cardiac surgery (I97.0-I97.1)
- intraoperative and postprocedural complications of specified body systems (D78.-, E36.-, E89.-, G97.3-, G97.4, H59.3-, H59.-, H95.2-, H95.3, I97.4-, I97.5, J95.6-, J95.7, K91.6-, L76.-, M96.-, N99.-)
- ostomy complications (J95.0-, K94.-, N99.5-)
- postgastric surgery syndromes (K91.1)
- postlaminectomy syndrome NEC (M96.1)
- postmastectomy lymphedema syndrome (I97.2)
- postsurgical blind-loop syndrome (K91.2)
- ventilator associated pneumonia (J95.851)
Use Additional- code for adverse effect, if applicable, to identify drug (T36-T50 with fifth or sixth character 5)
Complications of surgical and medical care, not elsewhere classified - T85
ICD-10-CM Diagnosis Code T85
Complications of other internal prosthetic devices, implants and grafts
2016 2017 2018 2019 2020 2021 2022 Non-Billable/Non-Specific Code
Type 2 Excludes- failure and rejection of transplanted organs and tissue (T86.-)
Complications of other internal prosthetic devices, implants and grafts - T85.610
ICD-10-CM Diagnosis Code T85.610
Breakdown (mechanical) of cranial or spinal infusion catheter
2016 2017 - Revised Code 2018 2019 2020 2021 2022 Non-Billable/Non-Specific Code
Applicable To- Breakdown (mechanical) of epidural infusion catheter
- Breakdown (mechanical) of intrathecal infusion catheter
- Breakdown (mechanical) of subarachnoid infusion catheter
- Breakdown (mechanical) of subdural infusion catheter
Breakdown (mechanical) of cranial or spinal infusion catheter
Present On AdmissionPOA Help
"Present On Admission" is defined as present at the time the order for inpatient admission occurs — conditions that develop during an outpatient encounter, including emergency department, observation, or outpatient surgery, are considered POA.
- T85.610S is considered exempt from POA reporting.
ICD-10-CM T85.610S is grouped within Diagnostic Related Group(s) (MS-DRG v39.0):
- 922 Other injury, poisoning and toxic effect diagnoses with mcc
- 923 Other injury, poisoning and toxic effect diagnoses without mcc
Convert T85.610S to ICD-9-CM
Code History
- 2016 (effective 10/1/2015): New code (first year of non-draft ICD-10-CM)
-
2017 (effective 10/1/2016): Revised code
- New description: Breakdown (mechanical) of cranial or spinal infusion catheter, sequela
- 2016 description: Breakdown (mechanical) of epidural and subdural infusion catheter, sequela
- 2018 (effective 10/1/2017): No change
- 2019 (effective 10/1/2018): No change
- 2020 (effective 10/1/2019): No change
- 2021 (effective 10/1/2020): No change
- 2022 (effective 10/1/2021): No change
ICD-10-CM Codes Adjacent To T85.610S
T85.598 Other mechanical complication of other gastrointestinal prosthetic devices, implants and grafts
T85.6 Mechanical complication of other specified internal and external prosthetic devices, implants and grafts
T85.61 Breakdown (mechanical) of other specified internal prosthetic devices, implants and grafts
T85.610 Breakdown (mechanical) of cranial or spinal infusion catheter
T85.610S
…… sequela
T85.611 Breakdown (mechanical) of intraperitoneal dialysis catheter
T85.612 Breakdown (mechanical) of permanent sutures
T85.613 Breakdown (mechanical) of artificial skin graft and decellularized allodermis
Reimbursement claims with a date of service on or after October 1, 2015 require the use of ICD-10-CM codes.